Product Specifications

Altherm ICF Block Specifications

Our premade forms fit together as large interlocking blocks. We use two EPS panels spaced apart by high strength polypropylene webs, that form an insulated permanent shuttering into which concrete is poured.

By using polypropylene webs, we further reduce thermal bridging. These webs maintain a core thickness between the EPS panels of either 150 mm (300 mm ICF block) or 200 mm (350 mm ICF block).


See below for further information about:

  • 300 mm Standard ICF Blocks
  • 350 mm ICF Block for Multi-Storey Apartments      & Commercial Buildings       
  • Declared Characteristics

300 mm - STANDARD ICF BLOCKS

  • Altherm ICF STRAIGHT BLOCK

300 mm Straight Form
Length x Height x Width (mm) 1200 x 400 x 300
Width of Concrete Form (mm) 150
Volume of Concrete (m³/m²) 0.014
Thermal Conductivity (λ) 0.030 W/m.K

300 mm Straight Form is comprised of two insulating EPS panels (75 mm thick) connected by high strength polypropylene webs. These webs maintain a core thickness between the EPS panels of 150 mm, where the concrete is poured.

  • Suitable for foundations & ground floor
  • Reversible
  • Altherm ICF CORNER block

300 mm Corner Form
Length x Height x Width (mm) 812 x 412 x 400 x 300
Width of Concrete Form (mm) 150
Volume of Concrete (m³/m²) 0.014
Thermal conductivity (λ) 0.030 W/m.K

300 mm Corner Form has 75 mm insulating panels on either side of a 150 mm core. The forms are 412 mm on the short side and 812 mm on the long side.

  • Suitable for foundations & ground floor
  • Reversible
  • Altherm ICF 300 size 160x75 with vertical cavity closer

300 mm Vertical Cavity Closer
Length x Height x Width(mm) 400 x 150 x 75

The 300 mm Vertical Cavity Closer slots neatly into either the 300 mm corner or straight forms to close off the concrete core at the sides of openings.

  • Fits into 300 mm straight or corner ends
  • Essential to minimise thermal bridging
  • Reversible
  • Altherm ICF Cavity Closers

300 mm Horizontal Cavity Closer
Length x Height x Width(mm) 1200 x 150 x 65

The 300 mm Horizontal Cavity Closer fits neatly into either the top or bottom of the 300 mm straight forms to close off the concrete core at the heads and sills of openings.

  • Fits into 300 mm straight or corner ends
  • Essential to minimise thermal bridging
  • Reversible

350 mm - ICF BLOCK FOR MULTI-STOREY APARTMENTS & COMMERCIAL BUILDINGS

  • Altherm ICF STRAIGHT BLOCK

350 mm Straight Form
Length x Height x Width(mm) 1200 x 400 x 350
Width of Concrete Form (mm) 200
Volume of Concrete (m³/m²) 0.019
Thermal conductivity (λ) 0.030 W/m.K

350 mm Straight Form provides a concrete core of 200 mm which is sufficient bearing for hollow core thickness between the EPS panels of 150 mm, where the concrete will be poured.

  • Suitable for multi-storey floors/apartments
  • Reversible
  • Altherm ICF CORNER block

350 mm Corner Form
Length x Height x Width(mm) 862 x 462 x 400 x 350
Width of Concrete Form (mm) 200
Volume of Concrete (m³/m²) 0.013
Thermal conductivity (λ) 0.030 W/m.K

350 mm Corner Form has 75 mm insulating panels on either side of a 200 mm core. The forms are 462 mm on the short side and 862 mm on the long side.

  • Suitable for multi-storey floors/apartments
  • Reversible


  • Altherm ICF 300 size 160x75 with vertical cavity closer

350 mm Vertical Cavity Closer

Length x Height x Width(mm) 400 x 200 x 75

The 350 mm Vertical Cavity Closer slots neatly into either the 350 mm corner or straight forms to close off the concrete core at the sides of openings.

  • Fits into 350 mm straight or corner ends
  • Essential to minimise thermal bridging
  • Reversible
  • Altherm ICF Cavity Closers

350 mm Horizontal Cavity Closer
Length x Height x Width(mm) 1200 x 200 x 65

The 350 mm Horizontal Cavity Closer fits neatly into either the top or bottom of the 350 mm straight forms to close off the concrete core at the heads and sills of openings.

  • Fits into 350 mm straight or corner ends
  • Essential to minimise thermal bridging
  • Reversible

Declared Characteristics

Essential Characteristic Technical Specification Product Performance
Declared Thermal Conductivity (50 mm) IS EN 12667 0.030 W/mK
Compressive Strength at 10% Deformation IS EN 826:2013 129 kPa
Bending Strength IS EN 12089:2013 329.65 kPa
EPS Density IS EN 1602:2013 Min 24 kg/m3
Reaction to Fire IS EN ISO 11925-2, IS EN 13501-1:2007 Euroclass E
Water Vapour Permeability IS EN 12086:2013 0.7208 mg/m·h·Pa
Water Absorption by Partial Immersion IS EN 12087:2013 0.23 kg/m2
Water Absorption by Total Immersion IS EN 12087 2.1 %

REQUEST A QUOTATION

Let us do some of the hard work and put together a comprehensive quote for your next project.

Send your drawings and programme details to our sales team for a project-specific quotation. Call +353 1 842 2823 or email info@altherm.ie